CVC Ordering Information
| Cross Reference Table | |
| Klipet Part# | Cross to |
| CVC | CVC |
![]() | CVC | Compact Current & Voltage Calibrator | $99.00 | Order Here |
Description
The Model CVC is a portable calibrator designed to meet the requirements of field calibration, testing, and troubleshooting of transducers, transmitters, actuators, and other process and control devices.
The Model CVC features a large, 0.59” (15 mm), LCD numerical display, with blue backlighting for use in dimly lit areas. Powered by a readily available standard 9V battery, it also comes with a 120V AC plug-in power supply for bench-top use.
Features
◊ 0.0 to 20.0 mA DC output in 1.0 mA steps
◊ 0.0 to 10.0 V DC output in 1.0 V steps
◊ Three output modes automatically selected by plug location
◊ Simulate using external loop supply (30 V DC Maximum)
◊ Source using internal 9V battery
◊ Voltage output
◊ Auto-Ramping with user adjustable minimum & maximum output values
◊ User adjustable ramp step time, 1 to 20 seconds, in 1 second increments
◊ User adjustable Auto-power-off time from 1 to 20 minutes in 1 minute increments
◊ 3-Position bail for pocket, hanging, or bench-top use
◊ Complete with :
*9V battery
*120 VAC plug-in power supply
*Test leads with alligator clips
*Carrying case
Specifications
| Outputs: | Ranges: |
Current: | 0.0 to 20.0mA DC in 1mA steps |
| Voltage: | 0.0 to 10.0V DC in 1V steps | ||
| Accuracy at 25°C (77°F): | Current: |
+/- 0.05mA DC | |
| Voltage: |
+/- 0.05V DC | ||
| Load Impedance: | Current: |
300 ohms maximum | |
| Voltage: | 1000 ohms minimum | ||
| External mA Transmitter Source: | Voltage: | 12V minimum to 30V peak maximum | |
| Ramping | Manual: | anywhere in range | |
| Auto: | Values: | user adjustable min. & max. values anywhere within range | |
| Step Time: | user adjustable from 1 to 20 seconds, in 1 second increments | ||
| Display: | Numerical: | LCD, 00.0 to 99.9, 0.59” H (15 mm) | |
| Annunciators: | “RAMP”, “OVER LOAD”, “mA”, “V”, “TIME”, and symbol for low battery | ||
| Blue Backlight: | energized with momentary side switch | ||
| Environmental: | Operating temperature: | 32 to 122°F (0 to 50°C) | |
| Power: | 9V Battery: |
NEDA1604, JIS006P, or IEC6F22 (Duracell MN1604 or equivalent); up to 30 hours continuous use | |
| Low Battery: | indicator comes on below approximately 7 volts | ||
| 120 VAC: | plug-in 9VDC output supply for bench-top use | ||
| Auto Power Off: | user adjustable delay time from 1 to 20 minutes after last key press can also be disabled | ||
| Physical: | Dimensions: | 5.5”H x 2.5”W x 1.4”D (140H x 63.5W x 35.6D mm) |
|
| Weight: | 6 oz (170 g) | ||